Micro-modular PLC Splitter

    Feartures

    • Small size and Achieve 0.9mm loose tube fiber optic multi-channel direct output without splitter;
    • SC adapterinterface default,can change interface type by the demand of customer;
    • Satisfy with industry standards YD/T893 and YD/T1117.


    Applications

    • Installed in the cable connector box;
    • Installed in the module box;
    • Installed in the distribution box.

    Advantages

    • Not sensitive to wavelength, high uniformity;
    • Resistance to high and low temperature;
    • In line with the Telcordia GR-1209 and GR-1221 reliability requirements;
    • ISO9001 quality system certification.
       

Performance Specifications

1×N PLC Splitter (Measured at room temperature and excludes connector loss)

TYPE 1*2 1*4 1*8 1*16 1*32 1*64
Fiber Type 9/125 um SMF-28e or customer appoint
Operating Wavelength(nm) 1260~1650
Insertion Loss(dB) Typical 3.6 6.8 10.3 13.5 16.2 20.5
Max 4.0 7.5 10.8 14.0 17.0 21.5
Loss Uniformity(dB) Max 0.7 0.7 1.0 1.5 2.0 2.5
Polariation Dependent Loss(dB) Max 0.2 0.2 0.3 0.3 0.3 0.4
Directivity(dB) ≥55
Return Loss (dB) UPC:50  APC:55
Operating  Temperature (°C) -40~+85 Storage Temperature (°C)


2×N PLC Splitter (Measured at room temperature and excludes connector loss)

TYPE 2*2 2*4 2*8 2*16 2*32 2*64
Fiber Type 9/125 um SMF-28e or customer appoint
Operating Wavelength(nm) 1260~1650
Insertion Loss(dB) Typical 4.0 7.4 10.8 14.2 17.3 21.5
Max 4.5 7.8 11.2 14.6 18.2 22.0
Loss Uniformity(dB) Max 0.8 1.4 1.5 2.0 2.5 3.0
Polariation Dependent Loss(dB) Max 0.3 0.3 0.4 0.4 0.4 0.4
Directivity(dB) ≥55
Return Loss (dB) UPC:50  APC:55
Operating  Temperature (°C) -40~+85 Storage Temperature (°C)


1×N PLC Splitter (Measured at room temperature and includes connector loss)

TYPE 1*2 1*4 1*8 1*16 1*32 1*64
Fiber Type 9/125 um SMF-28e or customer appoint
Operating Wavelength(nm) 1260~1650
Insertion Loss(dB) Typical 4.0 7.0 10.8 14.0 16.5 21.5
Max 4.5 8.0 11.3 14.5 17.5 22.0
Loss Uniformity(dB) Max 0.7 0.7 1.0 1.5 2.0 2.5
Polariation Dependent Loss(dB) Max 0.2 0.2 0.3 0.3 0.3 0.4
Directivity(dB) ≥55
Return Loss (dB) UPC:50  APC:55
Operating  Temperature (°C) -40~+85 Storage Temperature (°C)


2×N PLC Splitter (Measured at room temperature and includes connector loss)

TYPE 2*2 2*4 2*8 2*16 2*32 2*64
Fiber Type 9/125 um SMF-28e or customer appoint
Operating Wavelength(nm) 1260~1650
Insertion Loss(dB) Typical 4.0 7.9 11.3 14.7 17.8 22.0
Max 4.5 8.3 11.2 15.0 18.7 22.5
Loss Uniformity(dB) Max 0.8 1.4 1.5 2.0 2.5 3.0
Polariation Dependent Loss(dB) Max 0.3 0.3 0.4 0.4 0.4 0.4
Directivity(dB) ≥55
Return Loss (dB) UPC:50  APC:55
Operating  Temperature (°C) -40~+85 Storage Temperature (°C)

Package informations

PORT 1*2 2*2 1*4 2*4 1*8 2*8 1*16 2*16 1*32 2*32 1*64 2*64
WxHxL (mm) 4x12x60 6x20x80

 
Ordering Information

SPLC                  
M=Micro-modular PLC=PLC Splitter Wavelength (nm) Port Input Fiber Length Output Fiber Length Input Fiber Type Output Fiber Type Fiber Standard Input Connector Output Connector
13=1310 15=1550 16=1260-1650 102=1*2 104=1*4 108=1*8 116=1*16 132=1*32 164=1*64 202=2*2 204=2*4 208=2*8 216=2*16 232=2*32 264=2*64   1=1M 2=2M 3=Customized 1=1M 2=2M 3=Customized 1=250um bare fiber 2=900um loose tube 3=900um tight tube 1=250um bare fiber 2=250um ribbon fiber 1=G652 2=G657A 3=G657B 0=None 1=FC/APC 2=FC/PC 3=SC/APC 4=SC/PC 5=LC/PC 6=ST 0=None 1=FC/APC 2=FC/PC 3=SC/APC 4=SC/PC 5=LC/PC 6=ST