HOME  |   ENGLISH   |  中文
Search
Home > Product> Fiber Optic Couplers&Splitter&WDM > Fiber Optic PLC Splitter
Stent type PLC Splitter

    Features

    •  Stent uses advanced engineering plastic;
    •  Quartz substrate integrated waveguide;
    •  Small size,wide rang of working waveguide,high reliability,good uniformity;
    •  Design according to customers'demand;
    •  Satisfy with industry standards YD/T893 and YD/T1117.

    Applications

    •  Installed in all types of fiber optic distribution equipment;
    •  Installed in all types of test instruments.

    Advantages

    •  Not sensitive to wavelength,high uniformity;
    •  Resistance to high and low temperature;
    •  In line with the Telcordia GR-1209 and GR-1221 reliability requirements;
    •  ISO9001 quality system certification.
       

Performance Specifications

1×N PLC Splitter (Measured at room temperature and excludes connector loss)

TYPE 1*2 1*4 1*8 1*16 1*32 1*64
Fiber Type 9/125 um SMF-28e or customer appoint
Operating Wavelength(nm) 1260~1650
Insertion Loss(dB) Typical 3.6 6.8 10.3 13.5 16.2 20.5
Max 4.0 7.5 10.8 14.0 17.0 21.5
Loss Uniformity(dB) Max 0.7 0.7 1.0 1.5 2.0 2.5
Polariation Dependent Loss(dB) Max 0.2 0.2 0.3 0.3 0.3 0.4
Directivity(dB) ≥55
Return Loss (dB) UPC:50  APC:55
Operating  Temperature (°C) -40~+85 Storage Temperature (°C)


2×N PLC Splitter (Measured at room temperature and excludes connector loss)

TYPE 2*2 2*4 2*8 2*16 2*32 2*64
Fiber Type 9/125 um SMF-28e or customer appoint
Operating Wavelength(nm) 1260~1650
Insertion Loss(dB) Typical 4.0 7.4 10.8 14.2 17.3 21.5
Max 4.5 7.8 11.2 14.6 18.2 22.0
Loss Uniformity(dB) Max 0.8 1.4 1.5 2.0 2.5 3.0
Polariation Dependent Loss(dB) Max 0.3 0.3 0.4 0.4 0.4 0.4
Directivity(dB) ≥55
Return Loss (dB) UPC:50  APC:55
Operating  Temperature (°C) -40~+85 Storage Temperature (°C)


1×N PLC Splitter (Measured at room temperature and includes connector loss)

TYPE 1*2 1*4 1*8 1*16 1*32 1*64
Fiber Type 9/125 um SMF-28e or customer appoint
Operating Wavelength(nm) 1260~1650
Insertion Loss(dB) Typical 4.0 7.0 10.8 14.0 16.5 21.5
Max 4.5 8.0 11.3 14.5 17.5 22.0
Loss Uniformity(dB) Max 0.7 0.7 1.0 1.5 2.0 2.5
Polariation Dependent Loss(dB) Max 0.2 0.2 0.3 0.3 0.3 0.4
Directivity(dB) ≥55
Return Loss (dB) UPC:50  APC:55
Operating  Temperature (°C) -40~+85 Storage Temperature (°C)


2×N PLC Splitter (Measured at room temperature and includes connector loss)

TYPE 2*2 2*4 2*8 2*16 2*32 2*64
Fiber Type 9/125 um SMF-28e or customer appoint
Operating Wavelength(nm) 1260~1650
Insertion Loss(dB) Typical 4.0 7.9 11.3 14.7 17.8 22.0
Max 4.5 8.3 11.2 15.0 18.7 22.5
Loss Uniformity(dB) Max 0.8 1.4 1.5 2.0 2.5 3.0
Polariation Dependent Loss(dB) Max 0.3 0.3 0.4 0.4 0.4 0.4
Directivity(dB) ≥55
Return Loss (dB) UPC:50  APC:55
Operating  Temperature (°C) -40~+85 Storage Temperature (°C)


Package informations

PORT 1*2 2*2 1*4 2*4 1*8 2*8 1*16 2*16 1*32 2*32 1*64 2*64
WxHxL (mm) 4x4x40 4x4x40 4x4x40 4x4x40 4x4x40 4x4x45 4x7x50 4x7x50 4x7x60 4x7x50 4x7x60 4x12x60 4x12x60

 
Ordering Information

SPLC                    
S=Sent Type PLC=PLC Splitter Wavelength (nm) Port Input Fiber Length Output Fiber Length Input Fiber Type Output Fiber Type Between device and fan-out kit fiber type Fan-out kit type Input Connector Output Connector
13=1310 15=1550 16=1260-1650 102=1*2 104=1*4 108=1*8 116=1*16 132=1*32 164=1*64 202=2*2 204=2*4 208=2*8 216=2*16 232=2*32 264=2*64   1=1M 2=2M ...... 1=1M 2=2M ...... 1=250um bare fiber 2=900um loose tube 3=900um tight tube 1=900um loose tube 2=2mm cable 3=3mm cable 1=250um bare fiber 2=250um ribbon fiber 1=12core 0.9mm 2=12core 2.0mm 3=12core 3.0mm 4=24core 0.9mm 5=24core 2.0mm 6=24core 3.0mm 0=None 1=FC/APC 2=FC/PC 3=SC/APC 4=SC/PC 5=LC/PC 6=ST 0=None 1=FC/APC 2=FC/PC 3=SC/APC 4=SC/PC 5=LC/PC 6=ST